Bitzu

JN0-106 ยท Monitoring and maintenance

Interface statistics and errors

Interpreting show interfaces extensive and terse: admin and link status, input/output errors, CRC errors, drops and counters.

Key points

  • show interfaces terse: Admin (administrative state), Link (physical link), Proto (family on the logical unit), Local and Remote addresses.
  • Admin up, Link down: enabled, no physical link.
  • Admin down: disabled in configuration.
  • show interfaces extensive: traffic, input and output errors, drops, error types such as CRC.
  • Rising CRC or input errors: usually physical layer (cable, optic, port, speed/duplex mismatch).

Source: https://www.juniper.net/documentation/us/en/software/junos/cli-reference/topics/ref/command/show-interfaces-terse.html

Practice questions

Single choice

In show interfaces terse, what does Admin up combined with Link down mean?

  1. The interface is enabled but there is no physical link
  2. The interface is disabled in the configuration
  3. The interface has no IP address configured
  4. The interface is up but has no route
Show answer

Answer: A. The interface is enabled but there is no physical link

Admin reflects configuration and Link reflects the physical state, so this pair means enabled but no link. It is not an addressing or routing problem.

Select all that apply

Counters in show interfaces extensive show steadily growing input CRC errors. What are plausible causes?

  1. A damaged cable or dirty optic
  2. A speed or duplex mismatch with the neighbor
  3. A failing port or transceiver
  4. A missing static route
  5. A wrong OSPF area ID
Show answer

Answer: A. A damaged cable or dirty optic, B. A speed or duplex mismatch with the neighbor, C. A failing port or transceiver

CRC errors point to corrupted frames at the physical layer: a bad cable or dirty optic, a speed/duplex mismatch, or a failing port. Routing and OSPF area settings do not corrupt frames.

True or false

True or false: Link down in show interfaces terse always means someone disabled the interface in the configuration.

Show answer

Answer: False

False. Disabling shows as Admin down. Link down describes the physical state and can come from a missing cable, a dead peer or a faulty optic.

Practice 8 questions on this topic in Bitzu

Short lessons, instant explanations and spaced review of what you get wrong. Free on iOS and Android.

Download on the App StoreGet it on Google Play