N10-009 ยท Troubleshooting methodology, cabling and interfaces
Cable and signal problems
Wrong cable type, Cat 5/6/7/8, STP vs UTP, crosstalk, interference, attenuation, improper termination, TX/RX reversed.
Key points
- Cat 5e: 1 Gbps. Cat 6 and 6a: 10 Gbps (6a over the full 100 m). Cat 7/8: higher speeds, shorter reach.
- Single-mode vs multimode fiber must match the optics.
- STP resists interference better than UTP.
- Attenuation grows with length; crosstalk is bleed between pairs; EMI comes from motors and lights.
- Bad terminations (too much untwist, split pairs, open pins) and reversed TX/RX kill links.
Practice questions
Which copper category is the minimum that supports 10GBASE-T over the full 100 m channel?
- Cat 3
- Cat 5e
- Cat 6
- Cat 6a
Show answer
Answer: D. Cat 6a
Cat 6a is rated for 10 Gbps over 100 m. Cat 6 manages 10 Gbps only over a shorter distance, and Cat 5e and Cat 3 are too slow.
Which conditions can degrade a copper signal?
- Crosstalk between adjacent pairs
- A run longer than the 100 m limit
- An exhausted DHCP scope
- Interference from nearby motors or fluorescent ballasts
- A wrong access VLAN on the port
Show answer
Answer: A. Crosstalk between adjacent pairs, B. A run longer than the 100 m limit, D. Interference from nearby motors or fluorescent ballasts
Crosstalk, attenuation from excess length and EMI all weaken or corrupt the signal. DHCP exhaustion and VLAN mistakes are higher-layer problems.
Plugging a Cat 6 cable into two 1 Gbps ports makes the link run at 10 Gbps.
Show answer
Answer: False
Link speed is limited by the slowest component. The cable's rating is a ceiling, not a speed boost.
Practice 8 questions on this topic in Bitzu
Short lessons, instant explanations and spaced review of what you get wrong. Free on iOS and Android.